Filter by Category

Not applicable

Next

Part Number
Description
Manufacturer
Price & Lead Time
KS1434
4-CHANNEL DIGITAL INPUT TERMINAL 24 V DC FOR 2-WIRE SENSORS TYPE 2, EN 61131-2, FILTER 0.2 MS,
6 MA, 2-WIRE SYSTEM
BECKHOFF
Request Quote
KS1488
8-CHANNEL DIGITAL INPUT TERMINAL 24 V DC, FILTER 3.0 MS, 1-WIRE SYSTEM, NEGATIVE SWITCHING
BECKHOFF
Request Quote
KS1498
8-CHANNEL DIGITAL INPUT TERMINAL 24 V DC, FILTER 0.2 MS, 1-WIRE SYSTEM, NEGATIVE SWITCHING
BECKHOFF
Request Quote
KS1722
2-CHANNEL DIGITAL INPUT TERMINAL 120 V AC TO 230 V AC, WITHOUT POWER CONTACTS, 4-WIRE SYSTEM
BECKHOFF
Request Quote
KS2032
2-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 0.5 A WITH POLARITY PROTECTION, 4-WIRE SYSTEM
BECKHOFF
Request Quote
KS2114
4-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 0.5 A,
2 OUTPUTS 3-WIRE SYSTEM, 2 OUTPUTS 1-WIRE SYSTEM
BECKHOFF
Request Quote
KS2124
4-CHANNEL DIGITAL OUTPUT TERMINAL 5 V DC, 0.02 A,
2 OUTPUTS 3-WIRE SYSTEM, 2 OUTPUTS 1-WIRE SYSTEM
BECKHOFF
Request Quote
KS2134
4-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 0.5 A WITH POLARITY PROTECTION,
2 OUTPUTS 3-WIRE SYSTEMS, 2 OUTPUTS 1-WIRE SY...
BECKHOFF
Request Quote
KS2184
4-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, NEGATIVE SWITCHING, 0.5 A,
2 OUTPUTS 3-WIRE SYSTEMS, 2 OUTPUTS 1-WIRE SYSTEM
BECKHOFF
Request Quote
KS2212
2-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 0.5 A, 4-WIRE SYSTEM, DIAGNOSTICS FUNCTION
WIRE BREAKAGE AND OVERLOAD
BECKHOFF
Request Quote
KS2404
4-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 0.5 A WITH POLARITY PROTECTION, 2-WIRE SYSTEM
BECKHOFF
Request Quote
KS2408
8-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 0.5 A, TOTAL CURRENT 3 A, SINGLE-CONDUCTOR CONNECTION
BECKHOFF
Request Quote
KS2424
4-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 2 A WITH POLARITY PROTECTION, 2-WIRE SYSTEM
BECKHOFF
Request Quote
KS2488
8-CHANNEL DIGITAL OUTPUT TERMINAL 24 V DC, 0.5 A, TOTAL CURRENT 3 A, 1-WIRE SYSTEM, NEGATIVE SWITCHING
BECKHOFF
Request Quote
KS2512
2-CHANNEL PULSE WIDTH OUTPUT TERMINAL 24 V DC, 1.5 A, 4-WIRE SYSTEM, SWITCHING TO NEGATIVE POTENTIAL
BECKHOFF
Request Quote
KS2531
STEPPER MOTOR TERMINAL 24 V DC, 1.5 A, 2 PHASES, 2 DIGITAL INPUTS 24 V DC
BECKHOFF
Request Quote
KS2541
STEPPER MOTOR TERMINAL WITH INCREMENTAL ENCODER, 50 V DC, 5 A, 2 PHASES
2 DIGITAL INPUTS 24 V DC
4 DIGITAL INPUTS FOR AN...
BECKHOFF
Request Quote
KS2602
2-CHANNEL RELAY OUTPUT TERMINAL 230 V AC, 2 A, MAKE CONTACTS, 4-WIRE SYSTEM
BECKHOFF
Request Quote
KS2602-0010
2-CHANNEL RELAY OUTPUT TERMINAL 230 V AC, 5 A, MAKE CONTACTS, CONTACT-PROTECTING SWITCHING OF LED LAMPS
BECKHOFF
Request Quote
KS2612
2-CHANNEL RELAY OUTPUT TERMINAL 125 V AC, 0.5 A, CHANGE-OVER, 4-WIRE SYSTEM, NO POWER CONTACTS
BECKHOFF
Request Quote
KS2622
2-CHANNEL RELAY OUTPUT TERMINAL 230 V AC, 2 A, MAKE CONTACTS, 4-WIRE SYSTEM, NO POWER CONTACTS
BECKHOFF
Request Quote
KS2622-0010
2-CHANNEL RELAY OUTPUT TERMINAL, 230 V AC, 5 A, MAKE CONTACTS, NO POWER CONTACTS, CONTACT-PROTECTING SWITCHING OF LED LA...
BECKHOFF
Request Quote
KS2631
1-CHANNEL RELAY OUTPUT TERMINAL 400 V AC, 300 V DC, MAKE CONTACTS, 4-WIRE SYSTEM
BECKHOFF
Request Quote
KS2692
CYCLE MONITORING TERMINAL (WATCHDOG)
2 DIGITAL INPUTS 24 V DC
2 RELAY OUTPUTS, 230 V AC, 2 A, POTENTIAL-FREE NORMALLY-OP...
BECKHOFF
Request Quote
KS2722
2-CHANNEL TRIAC OUTPUT TERMINAL 12…230 V AC, 1 A WITH MUTUALLY LOCKED OUTPUTS
BECKHOFF
Request Quote
KS2732
2-CHANNEL TRIAC OUTPUT TERMINAL 12…230 V AC, 1 A WITH MUTUALLY LOCKED OUTPUTS
(WITHOUT POWER CONTACTS)
BECKHOFF
Request Quote
KS2784
4-CHANNEL DIGITAL OUTPUT TERMINAL 30 V AC/DC (INDUCTIVE), 48 V DC (OHMIC), 2 A, SOLID STATE RELAY
BECKHOFF
Request Quote
KS2794
4-CHANNEL DIGITAL OUTPUT TERMINAL 30 V AC/DC (INDUCTIVE), 48 V DC (OHMIC), 2 A, SOLID STATE RELAY, POTENTIAL-FREE
BECKHOFF
Request Quote
KS3001
1-CHANNEL ANALOG INPUT TERMINAL -10 V…+10 V, DIFFERENTIAL INPUT, 12 BIT
BECKHOFF
Request Quote
KS3002
2-CHANNEL ANALOG INPUT TERMINAL -10 V…+10 V, DIFFERENTIAL INPUT, 12 BIT
BECKHOFF
Request Quote
KS3041
1-CHANNEL LOOP-POWERED INPUT TERMINAL 0…20 MA, WITH POWER SUPPLY FOR TRANSDUCERS VIA POWER CONTACTS, 12 BIT
BECKHOFF
Request Quote
KS3042
2-CHANNEL LOOP-POWERED INPUT TERMINAL 0…20 MA, WITH POWER SUPPLY FOR TRANSDUCERS VIA POWER CONTACTS, 12 BIT
BECKHOFF
Request Quote
KS3051
1-CHANNEL LOOP-POWERED INPUT TERMINAL 4…20 MA, WITH POWER SUPPLY FOR TRANSDUCERS VIA POWER CONTACTS, 12 BIT
BECKHOFF
Request Quote
KS3052
2-CHANNEL LOOP-POWERED INPUT TERMINAL 4…20 MA, WITH POWER SUPPLY FOR TRANSDUCERS VIA POWER CONTACTS, 12 BIT
BECKHOFF
Request Quote
KS3102
2-CHANNEL ANALOG INPUT TERMINAL -10 V…+10 V, DIFFERENTIAL INPUT, 16 BIT
BECKHOFF
Request Quote
KS3132
2-CHANNEL ANALOG INPUT TERMINAL -10 V…+10 V, DIFFERENTIAL INPUT, 16 BIT, �0.05 % ACCURACY
BECKHOFF
Request Quote
KS3142
2-CHANNEL ANALOG INPUT TERMINAL 0…20 MA, DIFFERENTIAL INPUT, 16 BIT, �0.05 % ACCURACY
BECKHOFF
Request Quote
KS3152
2-CHANNEL ANALOG INPUT TERMINAL 4…20 MA, DIFFERENTIAL INPUT, 16 BIT, �0.05 % ACCURACY
BECKHOFF
Request Quote
KS3162
2-CHANNEL ANALOG INPUT TERMINAL 0…10 V, DIFFERENTIAL INPUT, 16 BIT, �0.05 % ACCURACY
BECKHOFF
Request Quote
KS3172
2-CHANNEL ANALOG INPUT TERMINAL 0…2 V, DIFFERENTIAL INPUT, 16 BIT, �0.05 % ACCURACY
BECKHOFF
Request Quote
KS3182
2-CHANNEL ANALOG INPUT TERMINAL -2 V…2 V, DIFFERENTIAL INPUT, 16 BIT, �0.05 % ACCURACY
BECKHOFF
Request Quote
KS3201
1-CHANNEL INPUT TERMINAL PT100 (RTD) FOR RESISTANCE SENSORS, 16 BIT, 3-WIRE SYSTEM
BECKHOFF
Request Quote
KS3202
2-CHANNEL INPUT TERMINAL PT100 (RTD) FOR RESISTANCE SENSORS, 16 BIT, 3-WIRE SYSTEM
BECKHOFF
Request Quote
KS3204
4-CHANNEL INPUT TERMINAL PT100 (RTD) FOR RESISTANCE SENSORS, 16 BIT, 2-WIRE SYSTEM
BECKHOFF
Request Quote
KS3222
2-CHANNEL INPUT TERMINAL PT100 (RTD) FOR 4-WIRE CONNECTION, HIGH-PRECISION
BECKHOFF
Request Quote
KS3228
8-CHANNEL INPUT TERMINAL PT1000, NI1000 (RTD) FOR RESISTANCE SENSORS, RESOLUTION 0.1 °C,
1-WIRE SYSTEM
BECKHOFF
Request Quote
KS3356
1-CHANNEL ACCURATE RESISTANCE BRIDGE EVALUATION, WITH SELF-CALIBRATION, 16 BIT
BECKHOFF
Request Quote
KS3361
1-CHANNEL OSCILLOSCOPE TERMINAL, -20 MV…20 MV, 100 ΜS SAMPLING TIME, DECENTRALISED ANALOG VALUE PROCESSING
BECKHOFF
Request Quote
KS3362
2-CHANNEL OSCILLOSCOPE TERMINAL, -10 V…+10 V, 100 ΜS SAMPLING TIME, DECENTRALISED ANALOG VALUE PROCESSING
BECKHOFF
Request Quote
KS3403
3-PHASE POWER MEASUREMENT TERMINAL, MAX. 500 V AC 3~, MAX. 1 A,
VIA MEASURING TRANSFORMERS X A/1A
BECKHOFF
Request Quote
KS3403-0010
3-PHASE POWER MEASUREMENT TERMINAL, MAX. 500 V AC 3~, MAX. 5 A,
VIA MEASURING TRANSFORMERS X A/5A
BECKHOFF
Request Quote

Next